Structural steel loses strength as it heats, so some steel frames must be protected to keep a building standing for a set time in a fire. Many single-storey steel frames need no protection to the frame, but multi-storey buildings and walls near a boundary follow different rules.
Steel loses strength and stiffness as it heats. In a fire, an unprotected steel member can reach a temperature at which it can no longer carry its load. Fire protection delays that point, so the frame keeps standing for the period the regulations require, which gives people time to leave and firefighters time to work.
In England, the guidance is Approved Document B, which supports Part B of the Building Regulations. Volume 2 covers buildings other than dwellings. Wales has its own Approved Document B, Scotland uses Section 2 of its building standards technical handbook, and Northern Ireland uses Technical Booklet E. BS 9999 is an alternative route, and the guidance in all four regions allows a fire safety engineered solution where the prescriptive route is not the best fit. The rules that apply depend on where the building is.
Single-storey buildings do not normally need structural fire resistance, and therefore need no fire protection to the frame. Section 7.3 of Approved Document B excludes from the definition of elements of structure anything that only supports a roof. A typical single-storey steel portal frame is therefore often left unprotected. Some owners or insurers still ask for protection, so confirm their requirements early.
Exceptions apply where a structural element also provides support or stability to:
The Steel Construction Institute publishes a design approach for single-storey steel frames in boundary conditions, known as SCI P313. In a boundary condition the fire resistance requirement applies to the boundary wall and the elements that support it. A specialist fire engineer should confirm the design for any building close to a boundary.
Multi-storey buildings follow a different route. The required periods of fire resistance come from Table B4 in Approved Document B and depend on the height of the building and its use. Height is measured from the ground to the upper surface of the top floor. Most non-residential multi-storey buildings in England are two, three or four storeys and less than 18 metres high, and for most of them the typical requirement is 60 minutes. Buildings between 18 and 30 metres typically need 90 minutes. Almost all buildings over 30 metres must also have a life safety sprinkler system.
Life safety sprinklers can be used to reduce the structural fire resistance required in most buildings under 30 metres, typically by 30 minutes. This is rarely done, because the cost of sprinklers is usually greater than the saving. Whether to use sprinklers is a decision for the design team and the building control body, and it should be made early because it changes the other answers.
When a steel element needs fire resistance there are four main routes.
The right choice depends on the period required, the finish, the programme and the cost. When a coating is applied in a workshop it becomes part of fabrication, so decide early so that the fabrication drawings include it.
Fire safety design is a shared responsibility. The architect and structural engineer set out the layout and the frame. A fire engineer may be appointed where the building is complex, close to a boundary or part of a larger scheme. The building control team, either the local authority or a private building control body, checks the proposal against the regulations. Ask your contractor to confirm who holds each role on your project and where the fire strategy is recorded.
The wall and roof cladding on a steel building is there for more than weather. Insulation materials and panel systems have their own fire classifications, and these should be confirmed against the building's use, its height and its distance from the boundary. Ask for the classification of the panels in writing before the specification is fixed.
A mezzanine or upper floor inside a steel frame changes the fire picture, because it adds floor loads and escape routes. The structure that supports it, and the stairs, may need fire resistance. Plan a mezzanine at the start of the design rather than adding it later.
Ask your design team or contractor to record three things in writing: whether any element of the frame needs fire resistance, why, and for how long. Ask how the distance to each boundary has been checked. Raise sprinklers early, because they change the answers.
MSB Group designs, fabricates and builds steel framed buildings under one contract, so these decisions are made once and carried through the drawings, the workshop and the site. See our steel framed buildings service and the guide to portal frame buildings. This article is general information, not fire engineering advice. Always confirm the requirements for your own building with a fire engineer and your building control body.
For more on how a frame is priced, read our steel frame building cost guide. Our guide to steel frame industrial buildings covers the wider design choices, and our article on design and build contracts explains how one team can carry the fire strategy from design to handover.
Often the frame does not, because Approved Document B excludes structure that only supports a roof. Walls near a boundary, separating walls, compartment walls and elements that support a gallery or a floor are exceptions.
It is a situation where an external wall must stay standing to stop fire spreading to a neighbouring building. The fire resistance requirement then applies to that wall and the elements that support it.
Thin film intumescent coatings, boards, sprays and concrete encasement. The choice depends on the period required, the finish, the programme and the cost.
In most buildings under 30 metres, life safety sprinklers can reduce the fire resistance required, typically by 30 minutes. Almost all buildings over 30 metres must have them.
No. Wales has its own Approved Document B, Scotland uses its building standards technical handbook and Northern Ireland uses Technical Booklet E.
Related service
Portal frame and steel framed buildings designed, fabricated and erected in house.